This Power AC / DC Converter was designed for open air field applications, to be supportive for battery charge for mobiles from line voltage with high power.
		  The provided stands allows a stable distance to the earth and the required ventilation of the converter.
		  Input is electrically isolated from output according to EN 60950-1.
| Input voltage: | 230 Vac ±15 %, 50 Hz. | 
| Consumption: | max. 16 A sinusoidal conform to EN 61000-3-2 | 
| Output voltage: | 28 Vdc +3, -5 % for 85 A, 24 Vdc +3, -5 % for 100 A | 
| Output current: | max. 100 A 20 °C, limited for overload or increased temperature | 
| Output release: | only after proved connection with vehicles supply system | 
| Output protection: | no-load proof short-circuit proof | 
| Inrush current: | < 30 A pk at 230 Vac | 
| Efficiency: | typ. 83 % at 230 Vac and 20 to 80 % load | 
 
		Technical specifications 
		refer to data sheet: 00888
By courtesy of Rheinmetall Landsysteme GmbH
| Isolation voltage: | floating output in accordance to VDE 0554 | 
| MTBF: | >15.000 h at 25 °C | 
| Dimensions: | 300 x 480 x 191 mm, (W x D x H) with stands | 
| Weight: | ≤15 kg | 
| Housing: | ■  made of cast G-AlSi12 (DIN 1725) ■ two carrying handles integrated in the heat sink ■ captive connector covers ■ ground terminal M8 on rear ■ four pierced holes a’ Φ 25 mm for a steel cable as anti-theft device | 
| Protection: | IP 66 (EN 60529) | 
| Operating temp.: | -46 °C to +63 °C | 
| Humidity: | 95 % rel. with thawing | 
| Salt fog: | 5 % at 35 °C | 
| Vibration.: | Fig. 514.5C3 for wheeled vehicles | 
| Shock: | 10 x 10 g / 6 ms | 
| EMI / EMC: | MIL-STD-461C respectiv. D | 
| ESD.: | EN 61000-4-2 | 
| Lightning protect.: | STANAG 4145 / AEP4, annex a (Land) /07.1990 | 
| NEMP: | STANAG 4236, Issue 2 | 
1) 3m screened lead, 230 Vac with integrated 16 A PRCD-S guard circuit (TBD) and CEE – 230V respectively Souriau Series 847 connectors.
2) 5m screened lead (power supply to mobile) with VG 95234 connectors of type M-24-12PN, respectively 24-125 N